拉斯维加斯会议中心, Phase II Expansion

Las Vegas, Nevada

Award of Merit, Sports/Entertainment, and Award of Merit, Excellence in Sustainability

所有者:Las Vegas Convention and Visitors Authority

LEAD DESIGN FIRM, ARCHITECT:tvsdesign

GENERAL CONTRACTOR:Turner/Martin-Harris Joint Venture

土木工程师:Poggemeyer Design Group Inc.

STRUCTURAL ENGINEER:Magnusson Klemencic Associates Inc.

MEP ENGINEER:环境系统设计公司

分包商:轰炸电气;Brightview景观开发;Harris Rebar;ISEC Inc.;MMC承包商;滚动平原构造函数;st鱼电气;无聊的公司;W&W钢架


一种积极的快速轨道方法使项目团队能够进行这项9亿美元的会议中心扩展,以跟上不断增长的交付时间表(即使在Covid-19的限制之后也达到了限制之后),并在短短26个月内完成了完整的施工。

The expansion added 1.4 million sq ft to the convention center and included a modern exhibition hall, a 150-ft-tall atrium, 75 meeting rooms and a 25,000-sq-ft outdoor terrace.

游说

Photo by Josh Partee Photography

在大流行之前,拉斯维加斯会议中心第二阶段扩张的团队采用了各种策略,因此可以同时进行多个工作阶段。随着该项目接近70%的完成,大流行就完成了,该团队克服了供应链中断,并与州官员合作,为现场的1200名工人提供安全的环境。

安全挤作一团

Photo by Radioactive Productions

With the expansion consisting of four separate projects in one, the joint-venture team was divided into four subteams. Each team focused on one element of the project and partnered with more than 50 different trades to execute 4.4 million hours of work by more than 5,400 tradespeople. Key safety measures included a comprehensive onboarding process, daily safety huddles, regular lunches with small groups of workers to solicit feedback and ongoing reviews of all safety procedures.

aerial view

Photo by Radioactive Productions

The building is the first convention center to achieve both LEED and Green Globes certifications. Its green features include an automated people mover, ample electric vehicle charging stations, a highly efficient central plant and many low-water use features.

In addition, the site layout was designed to maximize ride-sharing opportunities, resulting in a reduced parking footprint of 40%. The reserved parking areas offer dual-port, high-speed charging stations. The central plant has variable speed pumps and a fully automated building energy management system to perform 15% above the minimum energy code. High-efficiency LED light fixtures feature occupancy sensors and integrated dimming controls, and digital sub-meters monitor indoor and outdoor lighting and process loads independently.

The project also contains approximately 2 MW of photovoltaic panels that offset a significant portion of the building’s energy consumption and overall carbon footprint.